Pitbull Non Metallic
Submersible Pumps

      Home       About Us       Products       Contact Us

  Products By Type
  Pumps

Godwin Dri-Prime Centrifugals
CD Series- Diesel Driven
High Volume & Medium Head

2"/3" CD75MA5 Pump
3" x 3" CD80D Pump
3" x 3" CD80M Pump
4" x 4" CD100M Pump
6" x 6" CD150M Pump
8" x 8" CD200M Pump
8" x 8" CD225M Pump
10" x 10" CD250M Pump
12" x 12" CD300M Pump
12" x 12" DPC300 Pump
HL Series Diesel Driven
Medium-High Volume & High Head

4" x 3" HL80M Pump
4" x 4" HL4M Pump
6" x 4" HL5MS Pump
6" x 6" HL5M Pump
8" x 6" HL6M Pump
8" x 6" HL6/TS-2 Pump
10" x 8" HL8M Pump
12" x 10" HL10M Pump
CD & HL Series - Electric Driven
Electric Dri-Prime
CD & HL - Sound Attenuated
Sound Attenuated Pumps

Godwin Heidra Submersibles and Diesel/Hydraulic Power Units
Hydraulic Submersible

Godwin Sub-Prime Submersibles
Electric Submersible

Godwin Dewatering Pump Systems
Dewatering Systems

More Pumps
Hydrostatic Pressure Pumps
Trash Handling Submersibles

Rentals - Pumps and Systems
Pump Rentals

Pitbull Tough Sump & Transfer
Pneumatic Displacement Pumps
Submersible Models
Submersible
Transfer Models
Self Priming Transfer
Sludge & Filter Press Models
Sludge & Filter Press
Other Models
Pitbull Pumps

  Solids/Liquid
  Dewatering systems

Turbo Phase Separator (TPS)
Technology Overview

Solids Removal and Concentrating Unit (SRCU)
Technology Overview
 

  Water Filtration
Amiad Filters
Plastic Filters
Steel Filters
Automatic Filters

Acme Strainers
Automatic Scraper Strainers
 
Manufacturer
Amiad Filtration
auto self-cleaning water filtration
Acme Strainers
auto self-cleaning scraper strainers
Chicago Industrial Pump
    Company sump & transfer pumps
Godwin Pumps
pump & systems rentals & sales
  Pitbull Non Metallic Submersible Pumps

Pitbull Model S4V
Non Metallic Submersible Pumps

The  Model S4V is a submersible pump capable of demanding service in highly corrosive sump and transfer conditions. Constructed of glass reinforces vinyl ester, the pump is resistant to hydrochloric acid, sulphuric acid, nitric, phosphoric, hydrofluoric, sodium hypo chlorite, sodium hydroxide and many other industrial chemicals.

Each pump is supplied with an AP200 pneumatic control panel, which automatically cycles the pump at the rate liquid flows to it.

Because the Pitbull has no dynamic seals or diaphragms, it will operate in aggressive chemicals without the typical maintenance headaches. Debris and solids can pass through the pump, unable to damage anything because the pump is hollow. There is literally nothing inside the pump for the fluid to attack.

Specifications

  • Weight: 228 lbs
  • Piping: 4” flange (#150)
  • Control panel: AP200   (all-pneumatic)
  • Volume: 14 gallons (US)
  • Maximum discharge head: 100 psi
  • Maximum solid: 1.75" diameter
  • Lowest submerged operating level: 18” (liquid depth)
Requirements
  • Compressed air or dry gas, > 40 psi
  • 3/4” npt air supply inlet
  • 40 micron filtration recommended

Model and Options Selection:

              Part Number Ø S4V __/ __/  __


Standard units:
#S4V = a 4" vinyl ester submersible pump with PVC checks and epdm seats.

Optional examples:
#S4V/PP/V = a 4" vinyl ester submersible pump with polypropylene checks and viton seats.
*Vinyl ester used is Ashland Chemical Hetron 922 Series. Direct equivalent is Dow Durakane 411-25

A complete pump contains: pump, inlet and discharge check valves, an AP200 control panel and 15’ of nitrile/polyester braided airlines (3)

Description of options:
‘FI’ flow inducement. This is an air powered, vacuum generator mounted to the exhaust valve of the control panel. It is operated by a manual ball valve: ‘open’ generates full suction force; with the valve ‘closed’ the pump runs as a standard, gravity fed unit This option is used on a submersed pumps. Vinylester pumps are sold as submersed units only.

Valve seat selection:
EPDM - goot heat and acid/base resistance. Tougher than viton but poor solvent resistance, use to 300ºF.
Viton - excellent resistance to oixidzers and solvents. Medium strength, use to 250ºF

Temperature Limits
Pump Chamber - 150ºF

PVC checks - 100ºF

Polypropylene checks - 130ºF

PVDF checks - 200ºF

AIR CONSUMPTION CHART
Headè
êFlow
10 ft
20 ft
40 ft
60 ft
80 ft
100 ft
140 ft
180 ft
220 ft
10 gpm
2
2.4
3.2
4.1
4.9
5.8
7.5
9.3
11
20 gpm
3.8
4.7
6.4
8.1
9.9
11.6
15.1
18.5
22
30 gpm
5.7
7
9.6
12.2
14.8
17.4
22.6
27.8
33
40 gpm
7.6
9.4
12.8
16.3
19.7
23.2
30.1
37.1
44
60 gpm
11.4
14
19.2
24.4
29.6
34.8
45.2
55.6
66
80 gpm
15.2
18.7
25.6
32.6
39.5
46.4
60.3
74.1
88
100 gpm
19
23.4
32
40.7
49.4
58
75.3
92.7
110
140 gpm
26.6
32.7
44.8
57
69.1
81.2
105.5
129.7
154
Example: 30 gpm @ 40 ft TDH requires 9.6 SCFM


AP200 Control Panel

Commonly Asked Installation/Application Questions
Where is the control panel mounted?
Place within the 15’ radius of the airlines, above the pump. Up to 20’  extra can be ordered (consult CIPC if more is required).

Can the airlines be hard-piped? 
Yes they can, but the ID’s of our standard lines must be matched. You will need an adapter from CIPC for one of the lines.

Can a pump be modified or made especially for my application?
Yes, there is almost always a way to make a unit fit and function with a custom design. 

Can the piping be reduced?
Smaller piping causes higher head and velocity, and the pump may pass things the piping can’t. Try to avoid dropping more than one pipe size.



      Home       About Us       Products       Contact Us

Pitbull Non Metallic